SQY-FF04
Category: Full Face Gas Mask  Publish Time: 2013-10-14 16:49 

SQY-FF04
Protected objects, according to the needs of different canisters that can protect a variety of toxic gases, respectively, vapors, toxic smoke smog

Expiratory resistance: less than 98 Pa, 30L/MIN

Vision: not less than 70% of the total field of vision, binocular vision is not less than 30%

Yasuaki performance: more than 1.5 hours without fogging lenses, no distortion, no distortion (-30 )

Tightness (smoke leakage coefficient): not more than 0.005%

 

Note

Allowed to find out the operating environment prior to use poison nature, concentration and amount of oxygen in the air, without the previous figure Operating conditions, the absolute prohibition of the use, when the gas concentration or the use of greater than a predetermined oxygen content in the air is less than 18%, the You can not use self-priming filtered gas mask, respirator regulations tolerated direct toxic gas concentrations greater than 0.5%, instead ducted.

Parts and should be checked before use airtight junction, the reasons should be checked if the leak occurred, for example, inappropriate or wear a mask selection is incorrect, damaged canisters rubber body break loose connections and other parts of the mask. Maintain good airtight mask to use.

Check all parts intact, without airway blockage or breakage, metal parts for rust, deformation, rubber is changed.

After connecting the entire respirator seal check, the simplest way is: Open the rubber bottom plug inhale, at this time if there is no air to enter, then the proof is properly connected, if any leakage, check the components are connected correctly.

Canisters should be strictly observed the effective time, must be recorded in the course of time used canisters, poison nature and concentration. If the documentary film canisters on cumulative time reaches the specified time, you should immediately stop using, in the course of non-random Unscrew the lid of the canister and prevent water or other liquids into the tank.

The product should not be above 65 ℃ environment and high temperature environment storage.

Canister after moisture will reduce antivirus capabilities, usually should tighten the lid, fasten the bottom plug to prevent water.

Antivirus breathing mask eye lens window, should prevent scratches wear, maintain clear vision

Antivirus respiratory supplies must be kept after use should be cleaned and disinfected.

Prev productSQY-FF03